TempcoHead1A.gif (3001 bytes)
Home | Back to Liquid Cooled Selector

Standard Sizes and Ratings
Extruder Size 2" to 2 1/2"

I.D.
in
O.D.
in
Width
in
Watts Volts Phase Cooling
Tube O.D.
Features Part
Number
Each Half
3.625 6.75 4.5 n/a n/a n/a 3/8 Cool only, RC - C/T CBH04375
4 6 2.5 375 230 1 n/a   CBH05632
4 6 5 n/a n/a n/a 1/2 Cool only, w/1"dia. hole at gap CBH04873
4 6 9.5 1500 240 1 n/a Heat only, (2) T/C holes top gap CBH03372
4.375 7.875 12.25 2000 230 1 1/2 (2) 1/8" NPT holes CBH01595
4.375 7.875 15.75 3000 230 1 1/2 RC - C/T CBH05651
4.375 8 16.25 3000 230 1 1/2 (2) 1/8" NPT holes, vented CBH01707
4.5 7 3.813 810 240 1 n/a Heat only CBH05603
4.5 7 4.375 810 240 1 3/8 T/C hole at gap CBH01320
4.5 6.25 10 2600 208 1 n/a Heat only, EP terminal box CBH04112
4.5 6.25 10 2600 380 1 n/a Heat only, EP terminal box CBH04113
4.75 6.75 3.625 960 230 1 n/a Heat only, (2) 3/4"dia. holes E/H CBH03322
4.75 7.875 11.813 3000 220 1 3/8 C2 Termination, box E/H CBH04848
5 8 6.75 1000 240 1 1/2 (1) 3/4" dia. Hole at gap on 1 end, BF C/T fittings CBH01621
5 8.5 8.5 2000 230 1 1/2 RC - C/T CBH04141
5 8.5 14 3300 230 1 1/2 Bolt clamp CBH05478
5 8 16.25 3500 240 1 1/2 Bolt clamp CBH04518
5.118 8.618 14.625 5000 240 1 1/2 RC - C/T CBH04425
5.25 7 7.5 2000 240 1 n/a Bronze, heat only, bolt clamp, 3"dia. vent hole CBH01976
5.25 8 12.25 2700 230 1 n/a 2"Lg. slot at gap top/bot. (2) 1/8 NPT holes E/H CBH04223
5.5 9 3.5 800 240 1 1/2 RC - C/T CBH05384
5.5 9 4 825 230 1 1/2   CBH04820
5.5 8.75 5.5 1050 230 1 3/8   CBH01023
5.5 8.5 5.5 1050 230 1 3/8 EP Terminal box CBH04672
5.5 8.75 5.5 1400 230 1 1/2 C4 Terminal CBH05266
5.5 8.75 5.5 1050 190 1 1/2 C4 Terminal CBH05698
5.5 9 8 2300 240 1 1/2 C7 Terminal box CBH03357
5.5 8 8 1500 240 1 1/2 (1) 3/4"dia. Hole, RC - C/T CBH09146
5.5 9 12 2325 230 3 1/2   CBH02858
5.5 8 13.5 3750 240 1 1/2 (4) 3/4"dia. Holes CBH09133
5.5 7.5 18 n/a n/a n/a 1/2 Cool only, RC - C/T CBH01511
5.627 9.25 9 1550 210 1 1/2 2 Elements E/H, RC - C/T CBH03005

Items in red are in Stock

Feature Abbreviations

E/H = Each Half C/T = Cooling tubes
CWW = Dual Set of Cooling Tubes CW = Single Set of Cooling Tubes
EP = Explosion Resistant Terminal Housing  MR = Moisture Resistant Terminal Housing
MPR = Moisture Proof Die Cast Aluminum Box RC = Non-Exposed Cooling Tubes/Recessed NPT Fittings