Standard Sizes and Ratings
Extruder Size 10"
| I.D. in |
O.D. in |
Width in |
Watts | Volts | Phase | Cooling Tube O.D. |
Features | Part Number |
| Each Half | ||||||||
| 14.5 | 18 | 8 | 4350 | 230 | 1 | 1/2 | CBH05506 | |
| 15 | 18.625 | 8 | 5000 | 230 | 1 | 5/8 | CWW - C/T | CBH03388 |
| 15 | 19 | 15.375 | 9000 | 230 | 1 | 1/2 | Bolt clamp, CWW - C/T | CBH04367 |
| 15.5 | 19 | 10 | 6750 | 240 | 1 | 1/2 | Self drain C/T | CBH05655 |
| 15.5 | 19 | 19.5 | 13800 | 230 | 3 | 1/2 | Self drain RC - C/T | CBH05358 |
| 15.75 | 19.25 | 15 | 10000 | 277 | 1 | 3/8 | CWW, C2 terminal box | CBH02242 |
| 17.5 | 21 | 9.5 | 4500 | 240 | 1 | 1/2 | CWW, RC - C/T | CBH03183 |
| 18 | 20 | 11.5 | 3500 | 480 | 1 | n/a | R1 Termination, segment heater, 82° coverage | CBH05002 |
| 19 | 22.5 | 18 | 15000 | 460 | 3 | 1/2 | C7 Terminal box | CBH04880 |
| 20.5 | 23 | 9 | 6000 | 240 | 1 | n/a | Heat only | CBH03338 |
| 31 | 33.5 | 7.5 | 7500 | 500 | 1 | n/a | 120° segment heater | CBH05712 |
| 36 | 40 | 4.5 | 3500 | 240 | 1 | 1/2 | RC - C/T, C2 terminal box | CBH04896 |
|
Feature Abbreviations |
|
| E/H = Each Half | C/T = Cooling tubes |
| CWW = Dual Set of Cooling Tubes | CW = Single Set of Cooling Tubes |
| EP = Explosion Resistant Terminal Housing | MR = Moisture Resistant Terminal Housing |
| MPR = Moisture Proof Die Cast Aluminum Box | RC = Non-Exposed Cooling Tubes/Recessed NPT Fittings |