TEMPCO Electric Heater Corporation |
|
|
|||||||||||||||
|
Quartz Tubular Elements Quartz heaters consist of a helically wound resistance coil
|
|||||||||||||||
|
Design Features
Dimensional
Specifications Electrical
Specifications Warning: Quartz Heaters are Designed to be Used in a Horizontal Position Only.
|
|||||||||||||||
Standard Sizes and Electrical Ratings with Type T1 Termination
For other Terminations a Part Number will be issued at time of order.
| Quartz Tube Diameter | Overall Length | Heated Length | Watts | Part Number | |||
| in | mm | in | mm | 120V | 240V | ||
| 3/8" | 14 | 355.6 | 12-1/2 | 317.5 | 480 | KRD00001 | KRD00002 |
| 20 | 508 | 18-1/2 | 469.9 | 720 | KRD00003 | KRD00004 | |
| 26 | 660.4 | 24-1/2 | 622.3 | 960 | KRD00005 | KRD00006 | |
| 38 | 965.2 | 36-1/2 | 927.1 | 1450 | KRD00007 | KRD00008 | |
| 48 | 1219.2 | 46-1/2 | 1181.1 | 1900 | — | KRD00009 | |
| 1/2" | 18 | 457.2 | 16-1/2 | 419.1 | 900 | KRD00010 | KRD00011 |
| 20 | 508 | 18-1/2 | 469.9 | 900 | KRD00012 | KRD00013 | |
| 26 | 660.4 | 24-1/2 | 622.3 | 1200 | KRD00014 | KRD00015 | |
| 36 | 914.4 | 34-1/2 | 876.3 | 1800 | KRD00016 | KRD00017 | |
| 38 | 965.2 | 36-1/2 | 927.1 | 1800 | KRD00018 | KRD00019 | |
| 42 | 1066.8 | 40-1/2 | 1028.7 | 1580 | KRD00020 | KRD00021 | |
| 48 | 1219.2 | 46-1/2 | 1181.1 | 1820 | KRD00022 | KRD00023 | |
| 50 | 1270 | 48-1/2 | 1231.9 | 2400 | — | KRD00024 | |
| 54 | 1371.6 | 52-1/2 | 1333.5 | 2060 | — | KRD00025 | |
| 60 | 1524 | 58-1/2 | 1485.9 | 2300 | — | KRD00026 | |
| 66 | 1676.4 | 64-1/2 | 1638.3 | 2540 | — | KRD00027 | |
| 72 | 1828.8 | 70-1/2 | 1790.7 | 2780 | — | KRD00028 | |
| 5/8" | 24 | 609.6 | 21 | 533.4 | 1075 | KRD00029 | KRD00030 |
| 26 | 660.4 | 23 | 584.2 | 1800 | KRD00031 | KRD00032 | |
| 30 | 762 | 27 | 685.8 | 1375 | KRD00033 | KRD00034 | |
| 38 | 965.2 | 35 | 889 | 2500 | — | KRD00035 | |
| 42 | 1066.8 | 39 | 990.6 | 1975 | KRD00036 | KRD00037 | |
| 48 | 1219.2 | 45 | 1143 | 2275 | — | KRD00038 | |
| 50 | 1270 | 47 | 1193.8 | 3400 | — | KRD00039 | |
| 54 | 1371.6 | 51 | 1295.4 | 2575 | — | KRD00040 | |
| 60 | 1524 | 57 | 1447.8 | 2875 | — | KRD00041 | |
| 62 | 1574.8 | 59 | 1498.6 | 4200 | — | KRD00042 | |
| 66 | 1676.4 | 63 | 1600.2 | 3175 | — | KRD00043 | |
| 72 | 1828.8 | 69 | 1752.6 | 3475 | — | KRD00044 | |
| Type T1 Standard Termination 10-32 thread screw terminal standard termination. |
|
|
|
Type T2 Panel Mount
Bushings 10-32 thread screw terminals with extension bushings for CRA/TRH housing assemblies. |
|
|
Type T3 End Caps with
Slots Slots in ceramic end caps are for mounting in grooved sheet metal housings. Coil tension and the slots hold the heater in place and allow for thermal expansion of the assembly. 1/4" quick-disconnect tabs standard for lead wire termination. Screw terminals optional. |
| Type ST Tabs with Slotted Holes 1/2" wide by 3/4" long, with a 9/32" by 3/8" slot. |
|
| Type FT Quick Disconnect Fuse Type Fuse type connector provides ease of installation. Connectors are 3/8" OD by 1/2" long brass. |
|
| Type L1 Straight-Out Leads 10" flexible lead wire externally spliced standard. If longer leads are required, specify. |
|
![]() |
Type C4 Ceramic Caps with Leads This termination provides 10-32 screw terminals insulated with ceramic terminal covers. Screws are pre-wired with 10" flexible lead wire. If longer leads are required, specify. |