KTE2 Series – 4.88" × 2.46" Housing
Watts/Square Inch vs. Temperature Data
Heater Wattage Heater FaceWatt Density* Heater Body
Temp @ 72°F**
Peak Emitted
Wavelength***(microns)
  Style S Style C Style S Style C Style S Style C
100 12.29 10.53 753 695 4.3 4.52
125 15.36 13.16 838 779 4.02 4.21
150 18.43 15.79 907 848 3.82 3.99
163 20.02 17.16 939 880 3.73 3.89
200 24.57 21.05 1020 959 3.52 3.68
250 30.71 26.32 1117 1049 3.31 3.46
300 36.86 31.58 1206 1130 3.13 3.28
325 39.93 34.21 1248 1169 3.05 3.2
350 43 36.84 1287 1206 2.99 3.13
400 49.14 42.11 1356 1276 2.87 3
500 61.43 52.63 1451 1389 2.73 2.82
540 66.34 56.84 1476 1422 2.69 2.77
600 63.16 1460 2.72
*Heater Face Watt Density
Watt density calculation is based on heater face surface area, which is a relative constant value used to relate different sizes of heaters. The 6 tube KTE (Style S) has a surface area 85.7% of a 7 tube unit and will operate at a temperature 16.6% higher than the 7 tube (Style C) unit. This relationship has been confirmed through laboratory testing on various sizes of KTE heaters.
**Heater Body Temp @ 72°F
Heater face temperature as measured with a type K thermocouple mounted directly on the heater face. Temperatures are for a single heater facing down with target re-radiation from an oxidized SS surface 3" from heater face. Operating temperatures (and emitted wavelength) will vary with application conditions such as higher ambient, target absorption properties, moving/stationary systems, and distance to target. The tabulated temperatures are averages compiled from standardized lab tests on different ratings and sizes of KTE heaters. Translucent tube testing showed that various reflector materials and surface conditions (bright, oxidized, etc.) had little or no effect on test results. Lower heater temperatures will occur if radiation is allowed to dissipate freely from the surface without target re-radiation (about 20-25% lower when facing up in open air).
***Peak Emitted Wavelength
Peak infrared radiation wavelength as calculated from Wien's Displacement Law, for the operating temperature shown, expressed in microns (µm). The emissivity of KTE quartz heaters is close to the ideal blackbody value of 1.0 (range is from .88 to .92). This has been confirmed by testing using a thermal infrared camera.

Tempco logo
  CORPORATE HEADQUARTERS
Tempco Electric Heater Corporation

607 N. Central Ave. | Wood Dale, IL 60191-1452 USA
Phone: 630.350.2252 | Toll Free: 888.268.6396
Fax: 630.350.0232 | Email: [email protected]

TEMPCO BRANCH OFFICES
We have Branch Offices located across the United States.

 


 

Tempco on LinkedIn       Tempco on Facebook       Tempco on Instagram       Tempco on Twitter       Tempco on YouTube

© 2024-2025 Tempco Electric Heater Corporation. All Rights Reserved.
top