Tempco Custom Heater Manufacturing

Duraband (Micaband) heater Specifications and Tolerances

Performance Ratings

Maximum Temperature: Standard Sheath: 900°F (482°C)

Nominal Watt Density: 20-45 W/in2 (3-7 W/cm2 )

Maximum Watt Density: Dependent on heater size and operating temperature.

Electrical Ratings

Maximum Voltage: 480VAC

Dual Voltage or 3-Phase: Available depending on heater design

Maximum Amperage:

  • Lead Wire Termination: 12.5A
  • Screw Terminations:
  • 8-32UNF—20A
  • 10-32UNF—25A

Resistance Tolerance: +10%, –5%

Wattage Tolerance: +5%, –10%

Exposed electrical wiring on band heater installations is a violation of Electrical Safety Codes including O.S.H.A.

Physical Size Construction Limitations

Minimum Width: 3/4" (19.1 mm)

Width Tolerance: ±1/16" (1.59 mm)

Minimum Inside Diameter: 7/8" (22.1 mm)

Nominal Gap: 3/8" (9.5 mm)—If a larger gap is required for probes or thermocouples, specify when ordering.

Built-In Brackets

Heater Width Number of Brackets
1-1/2" to 3" (38-76 mm) 1
3-1/8" to 5" (79-127 mm) 2
5-1/8" to 6-7/8" (130-145 mm) 3
7" to 10" (178-254 mm) 4
10-1/8" to 15" (257-381 mm) 5

Minimum ID and Width for Construction/Clamping Styles

  Min. ID Min. Width
Style in mm in mm
NB 2 50.8 1-1/4 31.8
NS 3 76.2 1-1/4 31.8
NE 2/1/02 63.5 1-1/4 31.8
SB 8-Jul 22.1 3/4 19.1
SS 2 50.8 3/4 19.1
SE 2/1/02 63.5 1-1/4 31.8
FB 1 25.4 3/4 19.1
FS 2 50.8 3/4 19.1
FE 2/1/02 63.5 1-1/4 31.8
SL 4 101.6 1-1/4 31.8
NSL 4 101.6 1-1/4 31.8
NEL 4 101.6 1-1/4 31.8
LT 7 177.8 1-1/2 38.1
LS 7 177.8 1-1/2 38.1
LE 7 177.8 1-1/2 38.1
TWL 1 25.4 1 25.4
RNB 5/1/02 134.7 1 25.4
RNS 10 254 1 25.4

Recommended Segments by Inner Diameter

Number of Segments ID Range ID Range
in mm
1 15-1/2" & Smaller 393.7mm & Smaller
2 15 1/2" to 28" 393.7mm to 711.2mm
3 15 1/2" to 45" 393.7mm to 1143mm
4 15 1/2" to 56" 393.7mm to 1422.4mm
6 15 1/2" to 86" 393.7mm to 2184.4mm
8 25" to 96" 393.7mm to 2438.4mm

 

 

Note: Refer to individual descriptions for further information. Actual heater minimums will be a combination of termination and construction/strap styles.

Tempco logo
  CORPORATE HEADQUARTERS
Tempco Electric Heater Corporation

607 N. Central Ave. | Wood Dale, IL 60191-1452 USA
Phone: 630.350.2252 | Toll Free: 888.268.6396
Fax: 630.350.0232 | Email: [email protected]

TEMPCO BRANCH OFFICES
We have Branch Offices located across the United States.

 


 

Tempco on LinkedIn       Tempco on Facebook       Tempco on Instagram       Tempco on Twitter       Tempco on YouTube

© 2023-2024 Tempco Electric Heater Corporation. All Rights Reserved.
top