Dimensional Specifications

Actual Diameter (in) 0.438 0.496 0.553 0.580 0.621 0.660 0.710 0.745 0.813 0.993
Actual Diameter (mm) 11.1 12.6 14.0 14.7 15.8 16.8 18.0 18.9 20.7 25.2
Diameter Tolerance: ±.005 (.127 mm)
Length Tolerance: ±2% of sheath length
Camber Tolerance: .020" (0.38 mm) per foot of length

 

Electrical Specifications

Diameter (in) 0.438 0.496 0.553 0.580 0.621 0.660 0.710 0.745 0.813 0.993
Maximum Voltage 240 240 240 240 480 480 480 480 480 480
Maximum Amperage 6.7 10.5 10.5 23 25 25 25 25 25 25

If tighter tolerances are required, consult Tempco.

 