Hi-Denisty Cartridge Heater (Metric Sizes) Specifications and Tolerances

Performance Ratings

Maximum Temperature: 1400°F (760°C)

Maximum Watt Density: 100-300 W/in2 (15.5-46.5 W/cm2) depending on heater size & operating temperature.

Note: The maximum operating temperature and the life expectancy of a cartridge heater is dependent on two main factors:
1. The maximum recommended sheath temperature (v1200°F for a standard heater)
2. The maximum ambient temperature for the termination selected.     Consult Tempco if you require a recommendation for your application.

Dimensional Specifications

Nominal Diameter6.581012.51620
 mm(in)mm(in)mm(in)mm(in)mm(in)mm(in)
Actual Diameter6.43-0.2537.92-0.3129.93-0.39112.42-0.48915.93-0.62719.91-0.784
Actual Diameter Tolerance±.05 mm (±.002″)
Minimum Length25.4-125.4-125.4-125.4-125.4-131.75(1-1/4)
Maximum Length914-36914-361219-481524-601829-721829-72
Length Tolerance Heaters up to 127 mm (5″) long±2.4(3/32)±2.4(3/32)±2.4(3/32)±2.4(3/32)±2.4(3/32)±3.2(1/8)
Length Tolerance Heaters over 127 mm (5″) long±2% of Sheath Length
Camber Tolerance Heaters to 305 mm (12″) long.25 mm (.010″) per 305 mm (12″) of length
Camber Tolerance Heaters over 305 mm (12″) long.50 mm (.020″) per 305 mm (12″) of length

With some force, Tempco Hi-Density Cartridge Heaters will normally flex enough to fit into a straight reamed hole.

Electrical Specifications

Nominal Diameter6.581012.51620
Maximum Voltage260260260380480*480*
Maximum Amperage (see next line for exceptions)4.44.46.710.52323
†Maximum Amperage for Types C1C, C1D, C2C, C2D, CS, F, M3, R1B, S1B, S2B, SA, W, & W3 & Terminations335.57.69.79.7
Maximum Wattage at 260V114011501740273059805980
Maximum Wattage at 380V399087408740
Maximum Wattage at 480V10,58010,580
Wattage TolerancePlus 5%, Minus 10%
Resistance TolerancePlus 10%, Minus 5%

*480V when applicable. Consult Tempco.

†Current carrying capacities are for ambient temperatures up to 482°F (250°C) with mica insulated lead wires.